Description
- Support digital and analog data input to ensure your algorithm fully meet the standard requirements.
- AI sync function unifies original TAF into comparable TAF.
- Error data and error timing can be displayed for advanced algorithm improvement
- Intuitive software interface allows user to complete the comparison within a few mouse clicks.
- Comparison result is identical with PhysioNet WFDB library software and can be exported to a report file.
Category | Detail |
---|---|
Supported Standards | IEC 60601-2-47、ANSI / AAMI EC57、YY 0885 |
Supported Databases | MIT-BIH、AHA、NST、CU、ESC |
Supported Test Options – 17 Required Capabilities |
• QRS Se、QRS +P • VEB Se、VEB +P、VEB FPR • VEB COU Se、VEB COU +P、VEB S_Run Se、VEB S_Run +P、VEB L_Run Se、VEB L_Run +P • RMS heart rate error • % beats missed、% N and S missed 、% V missed、% F missed 、Total SHUTDOWN time |
Supported Test Options – 25 Optional Capabilities |
• SVEB Se、SVEB +P、SVEB FPR • SVEB COU Se、SVEB COU +P、SVEB S_Run Se、SVEB S_Run +P、SVEB L_Run Se、SVEB L_Run +P • VF EP Se、VF EP +P、VF DU Se、VF DU +P、VF FPR、VF Time • AF EP Se、AF EP +P、AF DU Se、AF DU +P、AF FPR、AF Time • ST EP Se、ST EP +P、ST DU Se、ST DU +P |
TAF Format | • Binary-MIT annotation (*.atr) • Text-MIT Label (*.txt) • Text-AHA Label (*.txt) • Text-AAMI Label (*.txt) • Text -AHA 2 fields (*.txt) • Text -AAMI 2 fields (*.txt) |
Supported Time Unit |
• Sample Index (100Hz ~ 1500Hz) • Absolute Time |
Supported Report Export Format | TXT, CSV, Excel, Word |
- Support digital and analog data input to ensure your algorithm fully meet the standard requirements.
- Test data can be imported automatically via the pre-defined file format or input manually.
- Intuitive software interface allows user to complete the comparison within a few mouse clicks.
- Comparison result can be exported to a report file.
Category | Detail |
---|---|
Supported Standards | IEC 60601-2-25:2011、YY 0782-2010 |
Supported Databases | CTS、CSE |
Supported Test Options – CTS Amplitude | • P1 amplitude • P2 amplitude • Q amplitude • R amplitude • S amplitude • J amplitude • ST20 amplitude • ST40 amplitude • ST60 amplitude • ST80 amplitude • T amplitude |
Supported Test Options – CTS Interval & Duration Absolute | • P Duration • PR Interval • QRS Duration • QT Interval • Q Duration • R Duration • S Duration |
Supported Test Options – CSE Global Intervals | • P Duration • PR Interval • QRS Duration • QT Interval |
Supported Test Options – CSE Against NOISE (YY0782) | • P Duration • QRS Duration • QT Interval • 50 Hz noise • 60 Hz noise • High frequency noise • Baseline noise |
Supported Report | • CTS Amplitude Analog Testing Report • CTS Amplitude Digital Testing Report • CTS Absolute Interval and Duration Analog Testing Report • CTS Absolute Interval and Duration Digital Testing Report • CSE Global Intervals Testing Report • CSE Against NOISE Analog Testing Report • CSE Against NOISE Digital Testing Report |
Supported Report Export Format | RTF file (Compatible with MS Word) |